ProSciTech Safety Data Sheets ProSciTech Pty Ltd · proscitech.com.au

SAFETY DATA SHEET

Collodion 2% in Amyl Acetate, Sterile

Version 1Last reviewed 3 November 2025Catalogue: 12620-10, 12620-50, 12620-55, EMS12620-10, EMS12620-50, EMS12620-55

1. Identification

Product Identifiers

Product Name
Collodion 2% in Amyl Acetate, Sterile
Other Names
Sterile Collodion (Parlodion) 2% in Amyl Acetate
Product Number(s)
12620-10, 12620-50, 12620-55, EMS12620-10, EMS12620-50, EMS12620-55
CAS Number
628-63-7

Recommended use of the chemical and restriction on use

Laboratory chemicals.

Company Details

ProSciTech Pty Ltd
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au

Emergency Contact Details

ProSciTech Pty Ltd
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au

2. Hazards Identification

Classification of the substance or mixture

  • GHS02 Flame
  • Flammable Liquids 3 H226 Flammable liquid and vapour.

Label Elements

Flammable
Flammable
Signal Words
Warning
Hazard Statement(s)
Flammable liquid and vapour.
Precautionary Statement(s)
  • Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
  • Keep container tightly closed.
  • Ground/bond container and receiving equipment.
  • Use only non-sparking tools.
  • Take precautionary measures against static discharge.
  • Wear protective gloves/protective clothing/eye protection/face protection.

Primary route(s) of entry

Not available

Human Health

Inhalation
Not available
Ingestion
Not available
Eyes
Not available
Skin
(or hair) Take off immediately all contaminated clothing. Rinse skin with water/shower.

Environment

  • In case of fire: Use CO₂, powder or water spray to extinguish.
  • Store in a well-ventilated place. Keep cool.
  • Dispose of contents/container in accordance with local/regional/national/international regulations.

3. Composition / Information on Ingredients

NameCAS No.Content (w/w)Classification
AMYL ACETATE, REAGENT628-63-7>50-≤100%Not Available

4. First Aid Measures

Ingestion
If symptoms persist consult doctor.
Inhalation
Supply fresh air; consult doctor in case of complaints.
Skin Contact
Generally the product does not irritate the skin.
Eye Contact
Rinse opened eye for several minutes under running water.
Other Information
No further relevant information available.

5. Firefighting Measures

Suitable extinguishing equipment

Fire
CO₂, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
HAZCHEM
For safety reasons unsuitable extinguishing agents: Water with full jet.

Special protective equipment and precautions for fire fighters

No special measures required.

6. Accidental Release Measures

Personal precautions, protective equipment and emergency procedures
Wear protective equipment. Keep unprotected persons away.
Environmental precautions
  • Dilute with plenty of water.
  • Do not allow to enter sewers/surface or ground water.
Methods and materials for containment and clean up
  • Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
  • Do not flush with water or aqueous cleansing agents.

7. Handling and Storage

Precautions for safe handling
  • Keep ignition sources away - Do not smoke.
  • Protect from heat.
  • Protect against electrostatic charges.
Conditions for safe storage
  • Keep receptacle tightly sealed.
  • Protect from heat and direct sunlight.

8. Exposure Controls / Personal Protection

Exposure Standards

MaterialTWA ppmTWA mg/m³STEL ppmSTEL mg/m³
628-63-7 AMYL ACETATE, REAGENT100ppm525mg/m³100ppm525mg/m³
Engineering controls
Wash hands before breaks and at the end of work.

Personal protective equipment

Eye and face protection
Tightly sealed goggles.
Skin protection
  • Wear protective gloves. The glove material has to be impermeable and resistant to the product/the substance/the preparation.
  • Material of gloves
  • The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.
  • Penetration time of glove material
  • The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Body protection
Not available
Respiratory protection
Not required.

9. Physical and Chemical Properties

General information

Appearance
Colourless liquid
Odour
Fruit-like
pH
Not determined
Vapour Pressure
5.3 hPa
Density
0.8752 g/cm³
Boiling Point
149.25 °C (300.7 °F)
Melting Point
-70.8 °C (-95.4 °F)
Solubility
1.8g/l
Specific Gravity of Density
Not available
Flash Point
16 °C (60.8 °F)
Flammable (Explosive) Limits
  • Lower: 1.1 Vol%
  • Upper: 7.5 Vol%
  • Product is not explosive. However, formation of explosive air/vapour mixtures are possible.
Ignition Temperature
360°C (680 °F)
Formula
Not available

10. Stability and Reactivity

Reactivity
No further relevant information available.
Chemical stability
No decomposition if used according to specifications.
Possibility of hazardous reactions
No dangerous reactions known.
Conditions to avoid
No further relevant information available.
Incompatible materials
no further relevant information available.

11. Toxicological Information

Acute effects
Not available.
Eye contact
No irritating effect.
Skin contact
No irritant effect.
Ingestion
Not available
Inhalation
Not available
Toxicity and irritation
Not available.

12. Ecological Information

Ecotoxicity
No further relevant information available.
Persistence and degradability
No further relevant information available.
Bioaccumulative potential
No further relevant information available.
Other adverse effects
  • Water hazard class 1: slightly hazardous for water.
  • Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.

13. Disposal Considerations

General information

  • Must not be disposed of together with household garbage. Do not allow product to reach sewage system.
  • Disposal must be made according to official regulations.

14. Transport Information

ADG label required

Class 3 Flammable liquid
Class 3 Flammable liquid
HAZCHEM
For safety reasons unsuitable extinguishing agents: Water with full jet.
UN Number
UN1104
Proper shipping name
  • DOT RQ Amyl acetates
  • ADR 1104 AMYL ACETATES
  • IMDG, IATA AMYL ACETATES
Transport hazard class
Class 3 Flammable liquids
Packing group
III
Environmental hazard
Not applicable.
Special precautions for users
  • Warning: Flammable liquids
  • Hazard identification number (Kemler) code: 30
  • EMS Number: F-E
  • Stowage Category: A
Additional information
  • DOT
  • Quantity limitations:
  • On passenger aircraft/rail: 60L
  • On cargo aircraft only: 220L
  • Hazardous substance: 5000lbs, 2270kg
  • ADR
  • Excepted quantities (EQ) Code: E1
  • Maximum net quantity per inner packaging: 30mL
  • Maximum net quantity per outer packaging: 1000mL
  • IMDG
  • Limited quantities (LQ) 5L
  • Excepted quantities (EQ) Code: E1
  • Maximum net quantity per inner packaging: 30mL
  • Maximum net quantity per outer packaging: 1000ml

15. Regulatory Information

Poisons Schedule Number
Not available
Other Information
A Chemical Safety Assessment has not been carried out.

16. Other Information

SDS preparation date
3 November 2025
Comments
  • This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific features and shall not establish a legally valid contractual relationship.
  • Abbreviations and acronyms:
  • ADR: Accord relatif au transport international des marchandises dangereuses par route (European Agreement Concerning the International
  • Carriage of Dangerous Goods by Road)
  • IMDG: International Maritime Code for Dangerous Goods
  • DOT: US Department of Transportation
  • IATA: International Air Transport Association
  • EINECS: European Inventory of Existing Commercial Chemical Substances
  • ELINCS: European List of Notified Chemical Substances
  • CAS: Chemical Abstracts Service (division of the American Chemical Society)
  • NFPA: National Fire Protection Association (USA)
  • HMIS: Hazardous Materials Identification System (USA)
  • VOC: Volatile Organic Compounds (USA, EU)
  • PBT: Persistent, Bioaccumulative and Toxic
  • vPvB: very Persistent and very Bioaccumulative
  • NIOSH: National Institute for Occupational Safety
  • OSHA: Occupational Safety Health
  • TLV: Threshold Limit Value
  • PEL: Permissible Exposure Limit
  • REL: Recommended Exposure Limit
  • Flammable liquids 3: Flammable liquids - Category 3
References
EMS SDS Collodion 2% in Amyl Acetate 24/01/2023 https://www.emsdiasum.com/docs/technical/msds/12620-10.pdf