ProSciTech Safety Data Sheets ProSciTech Pty Ltd · proscitech.com.au

SAFETY DATA SHEET

Invoil B Vacuum Pump Oil

Version 1Last reviewed 24 February 2026Catalogue: 60720, M1-B-00500-X

1. Identification

Product Identifiers

Product Name
Invoil B Vacuum Pump Oil
Other Names
Formerly Apiezon B Oil
Product Number(s)
60720, M1-B-00500-X
CAS Number
68894-12-2

Recommended use of the chemical and restriction on use

Laboratory chemicals.

Company Details

ProSciTech Pty Ltd
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au

Emergency Contact Details

ProSciTech Pty Ltd
11 Carlton Street
KIRWAN QLD 4817
Australia
(07) 4773 9444
pst@proscitech.com
proscitech.com.au

2. Hazards Identification

Classification of the substance or mixture

The substance is not classified, according to the Globally Harmonised System (GHS).

Label Elements

Signal Words
None
Hazard Statement(s)
Not applicable
Precautionary Statement(s)
Not available.

Primary route(s) of entry

Not available.

Human Health

Inhalation
Not available
Ingestion
Not available
Eyes
Not available
Skin
Not available

Environment

Not available

3. Composition / Information on Ingredients

NameCAS No.Content (w/w)Classification
Hydrocarbon oil68894-12-2Substances

4. First Aid Measures

Ingestion
If symptoms persist consult a doctor.
Inhalation
  • Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if symptoms persist.
  • In case of unconsciousness place patient stably in side position for transportation.
Skin Contact
Immediately wash with water and soap and rinse thoroughly.
Eye Contact
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Other Information
Symptoms of poisoning may even occur after several hours; therefore medical observation for at least 48 hours after the accident.

5. Firefighting Measures

Suitable extinguishing equipment

Fire
Use fire extinguishing methods suitable to surrounding conditions.
HAZCHEM
No further relevant information available.

Special protective equipment and precautions for fire fighters

Mouth respiratory protective device.

6. Accidental Release Measures

Personal precautions, protective equipment and emergency procedures
Not required.
Environmental precautions
Do not allow to enter sewers/surface or ground water.
Methods and materials for containment and clean up
  • Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
  • Dispose contaminated material as waste according to item 13.
  • Ensure adequate ventilation.

7. Handling and Storage

Precautions for safe handling
  • Ensure good ventilation/exhaustion at the workplace.
  • Prevent formation of aerosols.
Conditions for safe storage
Keep container tightly sealed.

8. Exposure Controls / Personal Protection

Exposure Standards

Engineering controls
  • Keep away from foodstuffs, beverages and feed.
  • Immediately remove all soiled and contaminated clothing.
  • Wash hands before breaks and at the end of work.
  • Avoid contact with the eyes and skin.

Personal protective equipment

Eye and face protection
Tightly sealed goggles.
Skin protection
Wear protective gloves. The glove material has to be impermeable and resistant to the product/the substance/the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Body protection
Not available.
Respiratory protection
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.

9. Physical and Chemical Properties

General information

Appearance
Amber coloured liquid
Odour
Mild
pH
Not determined
Vapour Pressure
Not determined
Density
Not determined
Boiling Point
165°C
Melting Point
Undetermined
Solubility
Not miscible or difficult to mix
Specific Gravity of Density
Not available
Flash Point
196°C
Flammable (Explosive) Limits
Not determined
Ignition Temperature
Not determined
Formula
Not available

10. Stability and Reactivity

Reactivity
No further relevant information available.
Chemical stability
No decomposition if used according to specifications.
Possibility of hazardous reactions
No dangerous reactions known.
Conditions to avoid
No further relevant information available.
Incompatible materials
No further relevant information available.

11. Toxicological Information

Acute effects
Not available.
Eye contact
Irritating effect.
Skin contact
Irritant to skin and mucous membranes.
Ingestion
Not available.
Inhalation
No sensitising effects known.
Toxicity and irritation
Not available.

12. Ecological Information

Ecotoxicity
No further relevant information.
Persistence and degradability
No further relevant information available.
Bioaccumulative potential
no further relevant information available.
Other adverse effects
  • Water hazard class 1: Slightly hazardous for water.
  • Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.

13. Disposal Considerations

General information

  • Must not be disposed together with household garbage. Do not allow product to reach sewage system.
  • Disposal must be made according to official regulations.

14. Transport Information

ADG label required

HAZCHEM
No further relevant information available.
UN Number
Not regulated.
Proper shipping name
Not regulated.
Transport hazard class
Not regulated.
Packing group
Not regulated.
Environmental hazard
Not applicable.
Special precautions for users
Not applicable.
Additional information
Not available.

15. Regulatory Information

Poisons Schedule Number
Substance is not listed.
Other Information
A Chemical Safety Assessment has not been carried out.

16. Other Information

SDS preparation date
24 February 2026
Comments
This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship.