Special protective equipment and precautions for fire fighters
Wear self contained breathing apparatus for fire fighting if necessary.
6. Accidental Release Measures
Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Avoid breathing dust.
For personal protection see section 8.
Environmental precautions
Do not let product enter drains.
Methods and materials for containment and clean up
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal.
7. Handling and Storage
Precautions for safe handling
Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.Normal measures for preventive fire protection.
Conditions for safe storage
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
8. Exposure Controls / Personal Protection
Exposure Standards
Engineering controls
Not available.
Personal protective equipment
Eye and face protection
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the
standard EN 374 derived from it.
Full contact
Material: Nitrile rubber
Minimum layer thickness: 0.11 mm
Break through time: 480 min
Material tested:Dermatril® (KCL 740 / Aldrich Z677272, Size M)
Splash contact
Material: Nitrile rubber
Minimum layer thickness: 0.11 mm
Break through time: 480 min
Material tested:Dermatril® (KCL 740 / Aldrich Z677272, Size M)
data source: KCL GmbH, D-36124 Eichenzell, phone ±49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374
If used in solution, or mixed with other substances, and under conditions which differ from EN 374,
contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use
scenario.
Body protection
Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Respiratory protection is not required. Where protection from nuisance levels of dusts are desired, use type N95 (US) or type P1 (EN 143) dust masks. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
9. Physical and Chemical Properties
General information
Appearance
Crystalline
Odour
Not available.
pH
Not available.
Vapour Pressure
Not available.
Density
Not available.
Boiling Point
Not available.
Melting Point
288 °C - dec
Solubility
Not available.
Specific Gravity of Density
Not available.
Flash Point
Not available.
Flammable (Explosive) Limits
Not available.
Ignition Temperature
Not available.
Formula
C37H34N2Na2O9S3
10. Stability and Reactivity
Reactivity
No further relevant information available.
Chemical stability
Stable under recommended storage conditions.
Possibility of hazardous reactions
No further relevant information available.
Conditions to avoid
No further relevant information available.
Incompatible materials
Strong oxidising agents.
11. Toxicological Information
Acute effects
LD50 Oral - rat - > 2,000 mg/kg
Eye contact
No further relevant information available.
Skin contact
No further relevant information available.
Ingestion
No further relevant information available.
Inhalation
No further relevant information available.
Toxicity and irritation
To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated.
12. Ecological Information
Ecotoxicity
Toxicity to fish LC50 - Oryzias latipes - 1,000 mg/l - 48 h
Persistence and degradability
No further relevant information available.
Bioaccumulative potential
No further relevant information available.
Other adverse effects
No further relevant information available.
13. Disposal Considerations
General information
Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material. Dissolve or mix the material with a combustible solvent
and burn in a chemical incinerator equipped with an afterburner and scrubber.
This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship.