Do not induce vomiting without medical advice. Rinse with water.
Inhalation
Move to fresh air.
Skin Contact
Rinse with plenty of soap & water and seek medical advice.
Eye Contact
No further relevant information available.
Other Information
Notes to Physician: Treat symptomatically and supportively
5. Firefighting Measures
Suitable extinguishing equipment
Fire
Use dry chemical, CO₂, water spray or alcohol-resistant foam.
Specific Hazard: Carbon, nitrogen oxides
HAZCHEM
Not available.
Special protective equipment and precautions for fire fighters
Not considered to be a fire hazard. Not considered to be an explosion hazard. In the event of a fire, wear full protective clothing and NIOSH approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode.
6. Accidental Release Measures
Personal precautions, protective equipment and emergency procedures
Evacuate area. Wear self-contained breathing apparatus, rubber boots, and heavy rubber gloves.
Environmental precautions
Not available.
Methods and materials for containment and clean up
Ventilate area of leak or spill. Clean-up personnel may require respiratory protection from dust. Spills: Sweep up and containerize for reclamation or disposal. Vacuuming or wet sweeping may be used to avoid dust dispersal.
7. Handling and Storage
Precautions for safe handling
Do not breathe dust. Avoid contact with eyes, skin, and clothing. Avoid prolonged or repeated exposure. Wash thoroughly after handling.
Conditions for safe storage
Keep in a tightly closed container, stored in a cool, dry, ventilated area. Protect against physical damage. Isolate from incompatible substances.
8. Exposure Controls / Personal Protection
Exposure Standards
Material
TWA ppm
TWA mg/m³
STEL ppm
STEL mg/m³
Malachite Green
-
-
-
-
Engineering controls
Facilities storing or utilising this material should be equipped with an eyewash facility and safety shower. Use adequate ventilation to keep airborne concentrations low. A local exhaust system which captures the contaminant at its source is recommended to prevent dispersion of the contaminant into the workroom air.
Personal protective equipment
Eye and face protection
Use chemical safety goggles. Contact lenses should not be worn when working with this material. Maintain eye wash fountain and quick-drench facilities in work area.
Skin protection
Wear protective gloves. 0.11mm thick nitrile.
Body protection
Wear a clean body-covering clothing.
Respiratory protection
For conditions of use where exposure to the dust is apparent, a dust/mist respirator may be worn. For emergencies, a self-contained breathing apparatus may be necessary.
9. Physical and Chemical Properties
General information
Appearance
Green metallic crystalline powder
Odour
Odourless
pH
Not available.
Vapour Pressure
Not available.
Density
Not available.
Boiling Point
Not available.
Melting Point
144-150°C (291-302°F)
Solubility
Not available.
Specific Gravity of Density
Not available.
Flash Point
Not available.
Flammable (Explosive) Limits
Not available.
Ignition Temperature
Not available.
Formula
C23H25N2.C2HO4.0.5C2H2O4
10. Stability and Reactivity
Reactivity
No further relevant information available.
Chemical stability
Stable under ordinary conditions of use and storage.
Possibility of hazardous reactions
Hazardous Decomposition Products: May form carbon & nitrogen oxides when heated to decomposition.
Conditions to avoid
No further relevant information available.
Incompatible materials
Decomp. Temp.: 164°C (327°F)
11. Toxicological Information
Acute effects
No further relevant information available.
Eye contact
No further relevant information available.
Skin contact
No further relevant information available.
Ingestion
May cause stomach irregularities, DNA damage.
Inhalation
No further relevant information available.
Toxicity and irritation
LD50/LC50: Oral rat 275mg/kg
12. Ecological Information
Ecotoxicity
LC50-Ictalurus punctatur-0.14mg/l-96h EC50-Water flea - 0.29 -48h very toxic to aquatic life.
Persistence and degradability
No further relevant information available.
Bioaccumulative potential
No further relevant information available.
Other adverse effects
No further relevant information available.
13. Disposal Considerations
General information
Whatever cannot be saved for reclamation may be delivered to an approved waste disposal facility. Ensure compliance with local, state and federal regulations. Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. US EPA guidelines for the classification determination are listed in 40 CFR Parts 261.3. Additionally, waste generators must consult state and local hazardous waste regulations to ensure complete and accurate classification.
This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship.